| JP 
      
  The ready-to-use Fuel Cell:
Easy integration without expert knowledge!
 

Technical Data

 
Performance Data:
operation power 16 - 21 V DC
electrical output 450 W nominal, 500 W max.
current 18 A at nominal power
efficiency ~ 45% at 500 W
fuel supply Hydrogen 3.0
fuel consumption ~ 6.0 Nl/ min at 450 W
start-up time < 3 sec
lifetime 2000 h at 200 start/ stop-cycles
optimal working temperature 55 °C (stack temperature)
Interfaces:
hydrogen-inlet 1/8" inside thread
pressure range 2 – 20 bar
electr. power connector 4 mm² screw terminal
controller interface SUB-D9 (RS232)
overcurrent protection 22 A (flink)
General Data:
dimensions (L x B x H) 244 mm x 155 mm x 180 mm
weight ~ 4.0 kg
noise emission ~ 25 dBA in 7 m distance
emissions water (humid air), heat
Installation requirements & Storage:
installation space (L x B x H) ≥ 255 mm x 215 mm x 190 mm
inclination to transverse axis 20° short-term, 10° permanent
inclination to longitudinal axis 20° short-term, 10° permanent
operating altitude max. 1500 m above sea
start temperature 5 – 35 °C
operating temperature 5 – 35 °C
storage temperature -10 – 55 °C
Dimensions:
Installation space:
Performance-Graph:
 

Intended use

SuSy500 is built exclusively for use in a complete system for providing electrical energy. SuSy500 must be used with hydrogen (quality: at least 3.0) as energy source.
The device may only be used when installed (total system). The specified technical parameters must be adhered. A stand-alone operation is not planned and is recommended only under certain conditions (e.g. laboratory environment) and under prior arrangement with balticFuelCells GmbH.
 

Safety

Do not operate at ambient temperatures above 45°C. Protect during operation from direct contact with water, solvents and other chemicals. Follow the instructions for installation space and the environmental conditions. Keep away from fire. During normal operation, the device emits a small amount of hydrogen, which can lead to an ignitable gas composition when used in a small, closed space. The device should only be used in a ventilated space, where emissions can be freely discharged.
Use recommended tools for installation and original equipment. Turn off the power of the device immediately when recognizing a defect. Opening the device, alteration, faulty installation and operation jeopardize safety and lead to loss of license and will void the warranty.
 
  HOME SUSY
Function
Advantages
Applications
Integration
Technical Data
EQUIPMENT
Air filter
Connections
SERVICE
Downloads
FAQ
Know-How
NEWS
Latest news
Events
Newsletter
CONTACT
Get in contact
Customer-Hotline
Press

Imprint  |  AGB  |  Company  |  Career  |  © Copyright 2017, balticFuelCells GmbH